On-Site | Accredited* | |
---|---|---|
Ambient | ||
Extrusion plastometer | ||
Heat sealer | ||
Humidity | ||
Infrared gun | ||
LIG | ||
RTD | ||
Solder station | ||
Temp calibrator | ||
Temp device | ||
Thermocouple | ||
Thermometer | ||
Water bath | ||
Process | ||
Autoclave | ||
Chart recorder | ||
Data logger | ||
Incubator | ||
Oven | ||
Refrigerator | ||
Temp chamber | ||
Temp controller | ||
Vacuum oven |
TEMPERATURE CALIBRATION SERVICES
Stay compliant and audit-ready with expert temperature calibration services that fit your schedule.
Temperature Measurement
Unless they are experienced with temperature, many people are unaware of the significance of even being a mere degree off. Aldinger's expert technicians and sophisticated equipment can calibrate your temperature measuring devices up to 1/1000th of a degree (Celsius) to make sure it is reading and displaying accurately.
Asset tracking
Aldinger’s services and complimentary asset tracking solutions are designed to eliminate these pain points, allowing your team to focus on what they do best.
Temperature calibration service overview
Browse the list below for a brief overview of some of the equipment we calibrate.
* Aldinger is accredited by A2LA to ISO/IEC 17025 standards
Scope of accreditation to ISO/IEC 17025:2017 & ANSI/NCSL Z540-1-1994
Aldinger Company
1440 Prudential Drive | Dallas, TX 75235
Dustin Detten | Phone: 214-638-1808
Valid to: June 30, 2026
Certificate number: 1509.01
Range | CMC (±) | Comments | |
---|---|---|---|
Temperature – Measuring equipment | |||
(30 to 300) °C (86 to 572) °F |
0.09 °C 0.16 °F |
Hart 1502A/5614 PRT in dry block |
Range | CMC (±) | Comments | |
---|---|---|---|
Temperature – Measuring equipment | |||
(-40 to 200) °C (-40 to 392) °F |
0.061 °C 0.11 °F |
Hart 1502A/5614 PRT in wet bath, in lab only |
Range | CMC (±) | Comments | |
---|---|---|---|
Temperature – Measure | |||
(-100 to 600) °C (-148 to 1112) °F |
0.64 °C 1.2 °F |
Fluke 51 with thermocouple |
|
(600 to 1200) °C (1112 to 2192) °F |
1.1 °C 2.0 °F |
Range | CMC (±) | Comments | |
---|---|---|---|
IR thermometer | |||
(-20 to 150) °C |
1.1 °C |
Mikron M340 (lab only) |
|
(Amb + 10 to 400) °C |
2.1 °C |
Omega BB703 |
|
Emissivity ≈ 0.95 Wavelength (8 to 14) μm |
Range | CMC (±) | Comments | |
---|---|---|---|
Humidity - Measure & measuring equipment | |||
(10 to 90) % RH |
3.4 % RH |
Hart 1502A/5614 PRT in wet bath, in lab only |
Don't see exactly what you're looking for?